Installation Guide
47
18-SG02D1-1A-EN
Item Unit TR15REG-EB TR20REG-DB TR20REG-DB-3
RATED POWER (KW)
LPG 15 20 20
NG 14 18 18
FREQUENCY (HZ) 50 60 60
SPEED (RPM) 3600 3600 3600
RATED VOLT (V) 230 (230/400) 120/240 120/208
RATED CURRENT (A)
LPG 65.2/27.2 83.3 95.8
NG 60.9/25.4 75 87.5
PHASE Single-phase Single-phase Three-phase
POWER FACTOR 1.0 (0.8) 1.0 1.0
PROTECTION LEVEL IP23 IP23 IP23
INSULATION F F F
POLE 2 2 2
The generator unit is assembled from a large number of integrated components, including the primary silent
cooling system, electronic speed control system, automatic power generating system, multi-energy power gen-
eration technologies, intelligent control systems, and ultra-low temperature starting technology.
Generator Components and Enclosure
The main frame and chassis are the primary structures to which all other component pieces are attached. The
structure makes up the main noise protection and reduction features of the generator set. Other component
parts include the chassis, Radiator compartments, electronic control box compartment, and electronic screen
board compartments.