3. Replacement of used oil lter with new oil lter
Replace old oil lter after the engine has cooled. The replacement cycle should be followed according to the
maintenance cycle schedule.
Steps for replacement:
• Use oil lter wrench to remove old oil lter. Turn to the left to loosen.
• Before installing new oil lter coat, gasket surface with a thin layer of oil before installation.
• Twist new lter to the right to tighten into place with a rm hand. Do not over or under tighten lter
• Start generator and run for several minutes. Check for leaks. Shut down unit and check oil level using
dipstick. Oil level should read between point A and point B on dipstick. If needed add additional oil. Do
not over ll.
Note: Use oil lter wrench if needed but don’t over tighten, the recommended torque is between
15N.M-20N.M. Dispose of used oil and lter properly: do not pour down drain or on ground.
Direction A: Tighten Direction B: Loosen
23
032-5095-1A-EN