3. Replacement of used oil lter with new oil lter
Replace old oil lter after the engine has cooled. The replacement cycle should be followed according to the
maintenance cycle schedule.
Steps for replacement:
Use oil lter wrench to remove old oil lter. Turn to the left to loosen.
Before installing new oil lter coat, gasket surface with a thin layer of oil before installation.
Twist new lter to the right to tighten into place with a rm hand. Do not over or under tighten lter
Start generator and run for several minutes. Check for leaks. Shut down unit and check oil level using
dipstick. Oil level should read between point A and point B on dipstick. If needed add additional oil. Do
not over ll.
Note: Use oil lter wrench if needed but don’t over tighten, the recommended torque is between
15N.M-20N.M. Dispose of used oil and lter properly: do not pour down drain or on ground.
Direction A: Tighten Direction B: Loosen
23
032-5095-1A-EN