16 RTAE-SVX001B-EN
Table 6. Lifting configuration selection
Tons Unit Length
(a)
Lift Configuration See
150S, 165S, 150 Standard and Extended
4-point Figure 8, p. 16
165, 180, 200, 225, 250 Standard
165, 180, 200, 225, 250 Extended
6-point Figure 9, p. 17
275 Standard
275 Extended
8-point Figure 10, p. 17
300 Standard and Extended
(a) Units are extended length if either of the following are selected:
Transformer (model number digit 28 = 1)
Harmonic Filtration Option (model number digit 29 = 1)
Units without Harmonic Filtration Option or Transformer (digits 28, 29 = 0X) are standard length.
Figure 8. 4-point lift configuration
96” (2438mm) Spreader Bar
Lifting Location 2
(Lifting location 3
located on other side of unit)
Lifting Location 1
(Lifting location 4
located on other side of unit)