Installation and Maintenance Manual
Table Of Contents
- Warnings, Cautions and Notices
- Model Number Description
- General Information
- Pre-Installation
- Unit Dimensions/Weights
- Installation - Mechanical
- Location Requirements
- Rigging
- Evaporator Piping
- Condenser Water Piping (RTWD Units Only)
- Refrigerant Relief Valve Venting
- RTUD Installation
- System Configuration
- Equivalent Line Length
- Liquid Line Sizing
- Discharge (Hot Gas) Line Sizing
- Example
- Refrigerant Charge Determination
- RTUD Chilled Water Flow Control
- Oil Charge Determination
- Outdoor Air Temperature Sensor Installation Requirements
- Fan Control for the Remote Air Cooled Condenser
- RTUD Condenser Elevation Setting
- Shipping Spacers
- Installation - Electrical
- RTWD/RTUD Operating Principles
- Controls Interface
- Pre-Start Checkout
- Unit Start-Up Procedures
- Unit Shutdown
- Service and Maintenance
- Diagnostics
- Wiring Schematics

6 RLC-SVX09H-EN
Model Number Description
Nameplates
The RTWD/RTUD unit nameplates are applied to the
exterior surface of the control panel door.
A compressor nameplate is located on each compressor.
Unit Nameplate
See Figure 1. Unit nameplate includes the following:
• Unit model and size descriptor.
• Unit serial number.
• Identifies unit electrical requirements.
• Lists correct operating charges of R-134a and Oil 48.
• Lists unit test pressures
• Identifies installation, operation and maintenance and
service data literature.
• Lists drawing numbers for unit wiring diagrams.
Compressor Nameplate
Compressor nameplate includes the following:
• Compressor model number.
• Compressor serial number.
• Compressor electrical characteristics.
• Utilization Range.
• Recommended refrigerant.
Model Number Coding System
Model numbers for unit and compressors are comprised
of numbers and letter which represent equipment
features.
See “RTWD Model Number,” p. 7 and “Compressor Model
Number,” p. 8 for details.
Each position, or group of positions, in a number or letter
is used to represent a feature. For example, from the chart,
we can determine that “F” in digit 8 of unit model number
indicates unit voltage is 460/60/3.
ASME Nameplate
The ASME nameplate is different for the evaporators,
condensers (RTWD only) and oil separators.The
evaporator nameplate is located on the left portion of the
shell.The insulation over the nameplate is intentionally
left unglued, for ease in viewing the nameplate.
The condenser nameplate is on the backside of the
condenser below circuit 2 compressor.
Figure 1. Unit nameplate
Figure 2. Location of ASME unit nameplate - front
Figure 3. Location of ASME unit nameplates - back
%VAPORATOR
!3-% L
Evaporator ASME Nameplate
/IL3EPARATOR
!3-%NAMEPLATES
#ONDENSER
!3-%NAMEPLATES
Condenser
ASME nameplates (RTWD only)
Oil Separator
SME Nameplates
Condenser ASME Nameplate
(RTWD only)