Specifications
8
22-1930-1C-EN
MODEL
S9X2B080U3PSAA
(a)
S9X2B080U4PSAA
(a)
S9X2C080U4PSAA
(a)
S9X2C080U5PSAA
(a)
— Unfired 29–4C Stainless Steel 29–4C Stainless Steel 29–4C Stainless Steel 29–4C Stainless Steel
Gauge (Fired)
20 20 20 20
ORIFICES — Main
Nat. Gas Qty. — Drill Size
4 - 45 4 - 45 4 - 45 4 - 45
LP Gas Qty. — Drill Size
4 - 56 4- 56 4- 56 4- 56
GAS VALVE
Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage
PILOT SAFETY DEVICE
Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS — Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot
Number 4 4 4 4
POWER CONN. — V/Ph/Hz
(h)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (In Amps)
11.3 11.3 11.3 14.4
Max. Overcurrent Protection (Amps)
15 15 15 15
PIPE CONN. SIZE (in.)
1/2 1/2 1/2 1/2
DIMENSIONS H x W x D H x W x D H x W x D H x W x D
Uncrated (In.)
34 x 17-1/2 x 28–3/4 34 x 17-1/2 x 28–3/4 34 x 21 x 28–3/4 34 x 21 x 28–3/4
Crated (In.)
35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
132/124 135/127 149/139 149/139
(a)
Meets Energy Star
(b)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For
Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
(c)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 — latest edition.
(d)
Based on U.S. government standard tests.
(e)
5 Speed constant torque ECM blower motor
(f)
Refer to the Vent Length Table in the Installer's Guide.
(g)
All S9X2 furnace models have a vent outlet diameter that equals 2 in.
(h)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODEL
S9X2C100U4PSAA
(a)
S9X2C100U5PSAA
(a)
S9X2D120U5PSAA
(a)
S9X2B040D2PSAA
(a)
TYPE
Upflow/Horizontal Upflow / Horizontal Upflow/Horizontal
Downflow
RATINGS
(b)
1st Stage Input BTUH (ICS) 65,000 65,000 78,000 26,000
1st Stage Capacity BTUH 63,050 63,050 75,660 25,220
2nd Stage Input BTUH 100,000 100,000 120,000 40,000
2nd Stage Capacity BTUH (ICS)
(c) (d)
97,000 97,000 116,400 38,800
1st Stage Temp. Rise (Min.-Max.)
25 - 55 25 - 55 35-65 25 - 55
2nd Stage Temp. Rise (Min.-Max.)
35 - 65 35 - 65 40-70 30 - 60
AFUE (%)
96.0 96.0 95.0 96.0
BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT
Diameter — Width (In.)
11 X 10 11 X 10 11 X 10 11 X 8
No. Used 1 1 1 1
Speeds (No.)
(e)
5 5 5 5
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP 1 1 1
1/3
RPM 1075 1075 1075 1075
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
PPrroodduucctt SSppeecciiffiiccaattiioonnss