Specification Sheet
8
22-1921-1C-EN
MODEL
S9V2B080U4PSBA
(a)
S9V2C080U5PSBA
(a)
S9V2C100U4PSBA
(a)
S9V2C100U5PSBA
(a)
Gauge (Fired)
20 20 20 20
ORIFICES — Main
Nat. Gas Qty. — Drill Size
4 - 45 4 - 45 5 - 45 5 - 45
LP Gas Qty. — Drill Size
4- 56 4- 56 5- 56 5- 56
GAS VALVE
Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage
PILOT SAFETY DEVICE
Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS — Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot
Number 4 4 5 5
POWER CONN. — V/Ph/Hz
(g)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (In Amps)
10.8 13.9 10.8 13.9
Max. Overcurrent Protection (Amps)
15 15 15 15
PIPE CONN. SIZE (in.)
1/2 1/2 1/2 1/2
DIMENSIONS H x W x D H x W x D H x W x D H x W x D
Uncrated (In.)
34 x 17-1/2 x 28–3/4 34 x 21 x 28–3/4 34 x 21 x 28–3/4 34 x 21 x 28–3/4
Crated (In.)
35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
135/127 149/139 154/144 155/145
(a)
Meets Energy Star
(b)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For
Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
(c)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 — latest edition.
(d)
Based on U.S. government standard tests.
(e)
Refer to the Vent Length Table in the Installer's Guide.
(f)
All S9V2 furnace models have a vent outlet diameter that equals 2 in.
(g)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODEL
S9V2D120U5PSBA
(a)
S9V2B040D3PSBA
(a)
S9V2B060D3PSBA
(a)
S9V2B080D3PSBA
(a)
TYPE
Upflow/Horizontal
Downflow Downflow Downflow
RATINGS
(b)
1st Stage Input BTUH (ICS) 78,000 26,000 39,000 52,000
1st Stage Capacity BTUH 75,660 25,220 37,830 50,440
2nd Stage Input BTUH 120,000 40,000 60,000 80,000
2nd Stage Capacity BTUH (ICS)
(c) (d)
116,400 38,800 58,200 77,600
1st Stage Temp. Rise (Min.-Max.)
35-65 25 - 55 25 - 55 30 - 60
2nd Stage Temp. Rise (Min.-Max.)
40-70 30 - 60 35 - 65 40 - 70
AFUE (%)
(c)(d)
96.0 96.0 96.0 96.0
BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT
Diameter — Width (In.)
11 X 10 11 X 8 11 X 8 11 X 8
No. Used 1 1 1 1
Speeds (No.)
Variable Variable Variable Variable
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP 1
1/2 1/2 1/2
RPM Variable Variable Variable Variable
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 10.5 5.7 5.7 5.7
COMBUSTION FAN — Type Centrifugal Centrifugal Centrifugal Centrifugal
PPrroodduucctt SSppeecciiffiiccaattiioonn