Specification Sheet

22-1921-1C-EN
39
SS99VV22CC110000DD55PPSSBBAA
Table 22. S9V2C100D5PSBA Heating Airflow
S9V2C100D5PSBA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter
1st Stage Capacity = 63,050
2nd Stage Capacity = 97,000
Heating
Airflow
Setting
Target
Airflow
External Static Pressure
0.1 0.3 0.5 0.7 0.9
Heating 1st
Stage
Low 1094
CFM 1094 1023 952 881 809
Temp. Rise 53 57 61 65 69
Watts 100 153 206 258 311
Medium Low 1296
CFM 1296 1212 1127 1043 958
Temp. Rise 45 48 51 55 58
Watts 156 216 276 337 397
Medium
(a)
1346
CFM 1346 1259 1171 1083 996
Temp. Rise 43 46 49 53 56
Watts 172 234 297 359 421
High
1620
CFM 1620 1515 1409 1304 1198
Temp. Rise 36 38 41 44 46
Watts 284 358 431 504 578
Heating 2nd
Stage
Low 1520
CFM 1437 1420 1403 1385 1368
Temp. Rise 62 63 63 64 65
Watts 236 308 380 453 525
Medium Low 1800
CFM 1744 1712 1680 1649 1617
Temp. Rise 51 52 53 54 55
Watts 378 462 545 629 713
Medium
(a)
1870
CFM 1811 1779 1747 1715 1683
Temp. Rise 49 50 51 52 53
Watts 421 508 594 681 768
High
2250
CFM 2211 2109 2006 1903 1800
Temp. Rise 40 42 45 47 49
Watts 714 817 920 1023 905
(a)
Factory Setting.
HHeeaattiinngg aanndd CCoooolliinngg AAiirrffllooww TTaabblleess