Specification Sheet
12
22-1921-1C-EN
Heating and Cooling Airflow Tables
SS99VV22BB004400UU33PPSSBBAA
Table 2. S9V2B040U3PSBA Heating Airflow
S9V2B040U3PSBA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter
1st Stage Capacity = 25,220
2nd Stage Capacity = 38,800
Heating
Airflow
Setting
Target
Airflow
External Static Pressure
0.1 0.3 0.5 0.7 0.9
Heating 1st
Stage
Low 468
CFM 468 452 437 421 406
Temp. Rise 49 51 54 56 58
Watts 27 58 90 121 152
Medium Low 598
CFM 552 600 647 694 741
Temp. Rise 43 39 36 32 28
Watts 41 76 112 147 183
Medium
(a)
634
CFM 583 635 687 739 791
Temp. Rise 39 36 33 30 27
Watts 48 83 118 153 189
High
1008
CFM 930 905 879 853 828
Temp. Rise 25 25 26 27 27
Watts 125 178 232 285 339
Heating 2nd
Stage
Low 650
CFM 633 636 639 643 646
Temp. Rise 57 57 57 56 56
Watts 48 92 135 179 223
Medium Low 830
CFM 760 786 813 840 866
Temp. Rise 48 46 45 43 41
Watts 82 132 182 232 282
Medium
(a)
880
CFM 792 817 842 867 892
Temp. Rise 44 44 43 43 42
Watts 94 142 189 237 284
High
1400
CFM 1337 1269 1200 1132 1063
Temp. Rise 27 29 31 32 34
Watts 335 376 417 458 499
(a)
Factory Setting.