Quick Reference Guide

5 UH-TS-1
A Complete Line of Gas Heating Products
Indirect Fired
High Efficiency Indoor
Gas Duct Furnace
Model GLND/GLPD
The Trane high efficiency indoor gas
duct furnaces can achieve annual fuel
savings of 20 to 25 percent or more
over conventional gravity vented
units. Features include a factory
installed flue vent fan and sealed flue
collector that control combustion and
excess air during the on-cycle. Heated
air no longer escapes through the
draft diverted opening during the off
cycle.
Energy saving intermittent pilot
ignition reduces gas losses. The pilot
operates only when required.
Horizontal power venting allows side
wall venting, smaller openings and
single wall vent pipe.
High Efficiency Indoor Gas Duct Furnace
GLND/GLPD 010 012 015 017 020 022 025 030 035 040
Input MBh 100.0 125.0 150.0 175.0 200.0 225.0 250.0 300.0 350.0 400.0
Output MBh 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Max CFM 2469 3086 3704 4321 4938 5556 6173 7407 8642 9877
Pressure Drop 0.90 0.80 0.75 0.75 0.75 0.75 0.80 0.90 0.90 0.90
Min. Temperature Rise F 30303030303030303030
Min. CFM 929 1157 1389 1620 1852 2083 2315 2778 3241 3704
Pressure Drop 0.12 0.13 0.15 0.14 0.14 0.14 0.14 0.13 0.13 0.14
Max Temperature Rise F 80808080808080808080
Flue Outlet (1) 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8"
Rec. Flue Size 4"R 4"R 4"R 4"R 5"R 5"R 5"R 6"R 6"R 6"R
1. All flue outlets are 5 1/8" O.D. ±1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 sizes.
Separated Combustion Indoor
Gas Duct Furnaces
Model GMND/GMPD
The Trane separated combustion
indoor gas duct furnace achieves
higher seasonal efficiencies by using
outside air for combustion. It
overcomes slight negative pressures
near exhaust fans or paint booths.
The burners, pilot and flue system are
totally enclosed within the unit,
isolated from dust, humidity and
chemicals in the atmosphere.
High Efficiency Centrifugal Fan Gas Unit Heater
GMND/GMPD 010 012 015 017 020 022 025 030 035 040
Input MBh 100.0 125.0 150.0 175.0 200.0 225.0 250.0 300.0 350.0 400.0
Output MBh 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Max CFM 3700 4625 5550 6475 7401 8326 9251 11101 12951 14801
Pressure Drop 2.03 1.92 1.81 1.86 1.90 1.93 1.96 2.00 2.02 2.05
Min. Temperature Rise F 20202020202020202020
Min. CFM 822 1028 1233 1439 1645 1850 2056 2467 2878 3289
Pressure Drop 0.10 0.09 0.09 0.09 0.09 0.09 0.09 0.10 0.10 0.10
Max Temperature Rise F 90909090909090909090
Flue Outlet (1) 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8"
Rec. Flue Size 4"R 4"R 4"R 4"R 5"R 5"R 5"R 6"R 6"R 6"R
Comb Air Inlet 4R4R4R4R5R5R5R60V60V60V
Rec. Flue Size 4"R 4"R 4"R 4"R 5"R 5"R 5"R 6"R 6"R 6"R
1. All flue outlets are 5 1/8" O.D. ±1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 sizes.