User's Manual
 4 22-1817-10
General 
Data
Product Specifications
Model No. 1  4TTX5018A1 4TTX5024A1 4TTX5030A1 4TTX5036A1
Electrical Data V/Ph/Hz 2 200/230/1/60 200/230/1/60 200/230/1/60 208/230/1/60
Min Cir Ampacity  8  11  15  22
Max Fuse Size (Amps)  15  20  25  35
Compressor CLIMATUFF
®
 CLIMATUFF
®
 CLIMATUFF
®
 CLIMATUFF
®
 - SCROLL 
No. Used - No Stages  1-1  1-1  1-1  1-1
RL Amps - LR Amps  6.2 - 38.6  8.6 - 57.8  11.1 - 63  16.7 - 79
Outdoor Fan FL Amps  0.74  0.74  0.74  0.93
Fan HP  1/8 1/8 1/8 1/5
Fan Dia (inches)  27.6  27.6  27.6  26.6
Coil  Spine Fin™  Spine Fin™  Spine Fin™  Spine Fin™
Refrigerant R-410A 6/09-LB/OZ 6/10-LB/OZ 6/10-LB/OZ 7/11-LB/OZ
Line Size - (in.) O.D. Gas 3 1/2 5/8 3/4 3/4
Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8
Dimensions H x W x D (Crated)  45.4 x 35.1 x 38.7  45.4 x 35.1 x 38.7  45.4 x 35.1 x 38.7  53.4 x 35.1 x 38.7
Weight - Shipping  271  275  276  283
Weight - Net  227  230  232  235
Start Components YES YES YES  NO
Sound Enclosure YES YES YES YES
Compressor Sump Heat  NO  NO  NO  NO
Optional Accessories: 4  
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C  AY28X079  AY28X079  AY28X079  AY28X079
Rubber Isolator Kit  BAYISLT101  BAYISLT101  BAYISLT101  BAYISLT101
Crank Case Heater Kit  BAYCCHT300  BAYCCHT300  BAYCCHT300  BAYCCHT301
Hard Start Kit Scroll        BAYKSKT260
Extreme Condition Mounting Kit  BAYECMT001  BAYECMT001  BAYECMT001  BAYECMT001
Snow Leg - Base & Cap 4" High  BAYLEGS002  BAYLEGS002  BAYLEGS002  BAYLEGS002
Snow Leg - 4" Extension  BAYLEGS003  BAYLEGS003  BAYLEGS003  BAYLEGS003
Seacoast Kit  BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001
Refrigerant Lineset 5 TAYREFLN850  TAYREFLN950  TAYREFLN7*  TAYREFLN7*
1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240.       
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.       
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.       
  For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
†
. (
†
denotes latest revision)       
4 For accessory description and usage, see page 5.       
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.       
63 125 250 500 1000 2000 4000 8000
4TTX5018A1 73 51 58 65.3 68.2 64.5 66.4 59 51.6
4TTX5024A1 74 51.5 59.6 64.3 71.5 70.5 64.8 58.6 52.8
4TTX5030A1 73 54.8 62.8 64.1 68.2 67.1 65.7 60.1 54.1
4TTX5036A1 72 53.7 58.9 62.1 66.8 66.8 61.2 58.8 45.4
4TTX5042A1 73 52 55.7 57.8 67.2 69.2 65 59.5 48.3
4TTX5048A1 73 52.1 55.9 68.3 67.1 65.4 62.2 58.6 48.8
4TTX5049E 72 43.8 53.6 56.8 60.9 61.9 57.2 50.4 40.7
4TTX5060A1 74 52.4 54.9 62.1 66.5 71.4 67.2 60.9 49.6
4TTX5061E 73 41.8 53.8 58 64.3 64.2 57.5 54 47.1
Note: Rated in accordance with AHRI Standard 270-2008.
 SOUND POWER 
LEVEL [dB(A)]
A-weighted Sound Power Level [dB(A)]
MODEL
 A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage