5.3.2 Group 2 Equipment Settings
MENU ITEM OPTIONS [DEAFULT] DESCRIPTION
Compressor Cooling Cycles Per Hour 2 - 6 [3] Select the number of cycles per hour during cooling operation
1st Stage Compressor Cooling Cycles Per Hour 2 - 6 [3]
Select the number of cycles per hour during 1st stage cooling
operation
2nd Stage Compressor Cooling Cycles Per Hour 2 - 6 [3]
Select the number of cycles per hour during 2nd stage cooling
operation
Compressor Heating Cycles Per Hour 2 - 6 [3] Select the minimum runtime (MRT) of stage 1 indoor heat
1st Stage Compressor Heating Cycles Per Hour 2 - 6 [3] Select the minimum runtime (MRT) of stage 2 indoor heat
2nd Stage Compressor heating Cycles Per Hour 2 - 6 [5] Select the minimum offtime (MOT) for indoor heat operation
Indoor Heater Cycles Per Hour 2 - 6 [5] Select the number of cycles per hour during indoor heat operation
1st Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 1st stage indoor heat
operation
2nd Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 2nd stage indoor heat
operation
3rd Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 3rd stage indoor heat
operation
5.3.3 Group 3 Sensors Settings
MENU ITEM OPTIONS [DEFAULT] DESCRIPTION
Select Outdoor Temperature Sensor
[No ODT Sensor],
Thermostat ODT Sensor
Select whether an outdoor temperature sensor has been connected
Calibrate Outdoor Temperature Sensor -5°F - 5°F Calibrate the outdoor temperature sensor
Select Indoor Temperature Sensor
[Thermostat IDT Sensor]
Wired IDT Sensor
Select whether the indoor temperature is being sensed by the thermostat
onboard sensor or wired remote sensor
Calibrate Indoor Temperature Sensor -5°F - 5°F Calibrate the indoor temperature sensor
Calibrate Onboard Humidity Sensor -5% - 5% Calibrate the onboard humidity sensor
Thermostat Humidity Sensor
[Disable],
Enable
Select whether to use the onboard humidity sensor when a wired indoor
remote temperature sensor is being used