User manual
2
Features and properties
• Simple operation
• Realistic signal and barrier operations
• Stop electromagnet outputs (Car system)
• Independent handling of two tracks per module
• Expandable to unlimited number of tracks
Technical parameters
Supply voltage: 7 – 24 V AC/DC
Idle mode current consumption: 20 mA
Max. current consumption: 500 mA
Dimensions: 47 x 37 mm
Short description
The circuit enables the automatic operation of a light barrier and a
lifting barrier on two tracks independent of each other. The track is
passable from both directions; the module gives a "free" signal
only when both tracks are released.
As the vehicle passes the sensors (e.g. TM-73379: Reflective
object sensor) it activates the red blinking signal. Thereafter also
the barrier closes with a delay. As soon as the last carriage has
passed the given sensor, the barrier will be released; the light
signal will be turned off with a delay.
No direction distinction is required at the sensors along the given
track section! Each sensor will automatically obtain a locking or
release function.
Inputs
The module supply voltage is to be connected to the POWER
input.