User manual

2
Features and properties
It can be used with analog and digital systems
No individual power supply requirement
Galvanically isolated outputs
Four independent channels
Easy connection to the block occupancy feedback device
Technical parameters
Input supply voltage: 4 – 24 V
Idle mode current consumption: 0 mA
Max. transfer current: 1 A
Max. output current: 50 mA
Dimensions: 48 x 32 mm
Short description
The circuit serves for checking the occupancy of four independent
blocks. Detection is based on the current consumption monitoring
of the blocks.
The output is a galvanically isolated.
Wiring
The blocks connected to the module rail output connector are
supplied by the current flowing along the common wire (Figure 1:
lower, thick blue line).
LEDs or digital feedback modules can be connected to the detector
outputs (upper outputs on the figure).