User manual

2
Features and properties
Can be linked to accessory decoder
High load current
No external power supply required
Technical parameters
Input supply voltage: 7 – 24 V
Idle mode current consumption: 0 mA
Max. current consumption: 1000 mA
Dimensions: 30 x 10 mm
Short description
By means of the module, completing the traditional accessory
decoder, it is possible to use motor operated switch mechanisms
(Conrad order No.: 219999, Tillig Elite etc.).
Motor operated switch mechanisms have the advantage of slow
and continuous motion.
Wiring
The module can be connected to the output of the accessory
decoder as indicated in Figure 1.
The motion of the motor operated switch mechanism can be
slowed down by inserting a 330-560 Ohm resistance between the
module and the motor.
If the motor operated switch mechanism has no limit stop, use the
accessory decoder (TM-22332) in pulse mode!