User Manual

Revision A (Dated 05/01/13) 6
from the weld surface. Care should be taken when applying heat to plastic to insure that the
melting occurs only as desired.
NOTE: Repairing a crack or hole DOES NOT return the plastic to its original strength,
although most repairs are sufficient to insure a water tight section. Monitoring of the repair
should be done for a short period after filling to insure that the repair has been done properly.
If leaks cannot be prevented, the section should be replaced.
In addition, if there has been an impact, the T-pins may be difficult to remove for wall realignment
since some sections have been compressed. A fork lift will facilitate wall realignment if necessary,
without removing the T-pins or to relieve the force on the T-pins. NOTE: When moving the full
water wall, use the two forklift pockets located at the bottom of the wall.
Figure 6: Clear Zone Diagram and Chart Recommendation