BUILD-IN INSTRUCTIONS TIMBERLINE & TIMBERLINE XL NOTE: This guide is designed to be used as a tool to assist the user when building their Timberline and Timberline XL into an outdoor kitchen space, and to ensure a safe and effective experience. DISCLAIMER: The built-in grill is mounted on casters. For a flush surface between grill and counter, refer to the Timberline Outdoor Kitchen Trim Kit.
IMPORTANT SAFETY PRECAUTIONS READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING YOUR TRAEGER® GRILL A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) BETWEEN COMBUSTIBLE MATERIALS AND YOUR GRILL. IT IS OF UTMOST IMPORTANCE THAT THIS PRODUCT BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS AND YOUR TRAEGER® GRILL OWNER’S MANUAL. Please read all instructions and warnings in this Installation Guide and your Traeger® Grill Owner’s Manual before installing.
CLEARANCE TO COMBUSTIBLE MATERIALS w WARNING Grill (free-standing or built-in) must maintain a minimum distance of 18" (45.7 cm) from any nearby combustibles, including wooden railing, home siding, window frames, furniture, trees, and trash receptacles, etc. NOTE: For clearance distance to combustible materials above the grill, refer to your local codes requirements for outdoor kitchens.
CABINET DESIGN AND MEASUREMENTS (MINIMUMS) A Minimum counter depth is 24" (61 cm). B See page 11 for receptacle location information. 1 Countertop must be wide enough for Induction Cooktop to be 3" (7.6 cm) from any edge (see page 7). 2 Recommended cabinet width for installing a Timberline XL is 50 13/16" (129.5 cm). If installing a Timberline, minimum cabinet width is 39 3/10" (99.8 cm).
GRILL CLEARANCES w WARNING A minimum distance of 2" (5.1 cm) from backsplash or another surface is required for the exhaust. C Recommended for ease of installation. D Required minimum distance for exhaust performance. Minimum 8 7/16" GRILL TO BACKSPLASH DISTANCE distance is 2" (5.1 cm).
LID CLEARANCE REQUIREMENTS E Maximum backsplash height is 39 27/32" (101.2 cm). F From rear face of grill barrel, lid overhang is approximately 12" (30.5 cm) E when lid is open.
INDUCTION COOKTOP LOCATION OPTIONS Timberline and Timberline XL Induction Cooktops are located on the left side of the grill, but can be built into either side of the cabinets in your outdoor kitchen. The Induction Cooktop must be a minimum of 3" (7.6 cm) from any edge. The Timberline Outdoor Kitchen Trim Kit includes a 6 ft. extension cord for the Induction Cooktop.
INDUCTION COOKTOP CUTOUT DIMENSIONS G Cooktop must be 3" (7.6 cm) from any edge. Dimensions provided are for the proper fit of the Induction Cooktop into the outdoor kitchen counter. A Dimensions in in Detail A must reference the red and blue lines on either side. Tolerance of measurements is +- 1/32" (unless otherwise specified).
INDUCTION COOKTOP VENTILATION IMPORTANT: • Ventilation is required for performance of the Induction Cooktop. • Exhaust and intake airflows must be separated for proper operation. • Keep the cabinet space below the Induction Cooktop empty for proper airflow and efficiency. H 18" (45.7 cm) is the minimum vent width for proper performance. I A minimum of 4.5" (11.45 cm) of empty space is required from the bottom of the Induction Cooktop.
INDUCTION COOKTOP PARTITION IMPORTANT: C • The exhaust and intake airflow must be separated for proper operation of the Induction Cooktop. C • The Induction Cooktop partition material must be NON-COMBUSTIBLE. J The closed cell foam rubber will need to be cut for the Induction Cooktop to sit properly in the countertop (see detail D).
OUTLET/POWER CORDS Review Electrical Shock Hazard in Important Safety Precautions. Defer to local ordinances for installation of electrical outlets. M Acceptable wall outlet locations N For Induction Cooktop power cord, a cutout will be needed on the inside wall of the cabinet (side of cooktop) to pass cord through. NOTES: • Induction Cooktop power cord length is 60" (152.5 cm). • Grill power cord length is 40.5" (102.9 cm).