Data Sheet
Input Current
- At no load
9 Vin models:
1 mA typ.
12 Vin models:
1 mA typ.
24 Vin models:
1 mA typ.
- At full load
9 Vin models:
1'000 mA max.
12 Vin models:
1'000 mA max.
24 Vin models:
1'000 mA max.
(at Vin min.)
Reflected Ripple Current
9 Vin models:
150 mAp-p typ.
12 Vin models:
150 mAp-p typ.
24 Vin models:
150 mAp-p typ.
Recommended Input Fuse
- 9 Vin input
1.2 Vout models:
630 mA (slow blow)
1.5 Vout models:
800 mA (slow blow)
1.8 Vout models:
800 mA (slow blow)
2.5 Vout models:
1'250 mA (slow blow)
3.3 Vout models:
1'250 mA (slow blow)
- 12 Vin input
5 Vout models:
1'600 mA (slow blow)
6.5 Vout models:
1'250 mA (slow blow)
- 24 Vin input
9 Vout models:
1'250 mA (slow blow)
12 Vout models:
1'600 mA (slow blow)
15 Vout models:
1'600 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Filter
Internal Capacitor
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (10 - 100%)
0.6% max. (1.2 & 1.5 Vout models)
0.4% max. (other models)
Ripple and Noise
(20 MHz Bandwidth)
1.2 Vout models:
50 mVp-p typ.
1.5 Vout models:
50 mVp-p typ.
1.8 Vout models:
50 mVp-p typ.
2.5 Vout models:
50 mVp-p typ.
3.3 Vout models:
50 mVp-p typ.
5 Vout models:
50 mVp-p typ.
6.5 Vout models:
50 mVp-p typ.
9 Vout models:
75 mVp-p typ.
12 Vout models:
75 mVp-p typ.
15 Vout models:
75 mVp-p typ.
Capacitive Load
470 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.015 %/K max.
Start-up Overshoot Voltage
1% max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
250% typ. of Iout max.
Transient Response
- Peak Variation
150 mV typ. / 200 mV max. (50% Load Step)
- Response Time
250 µs typ. / 350 µs max. (50% Load Step)
Output Specifications
EMI Emissions
- Conducted Emissions
EN 55032 class A (with external filter)
- Radiated Emissions
EN 55032 class A (with external filter)
External filter proposal:
www.tracopower.com/overview/tsr1
EMC Specifications
TSR 1 Series, 1 A
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
April 27, 2020