Data Sheet

Input Current
- At no load
3 mA typ.
Recommended Input Fuse
3.3 Vout models:
800 mA (slow blow)
5 Vout models:
800 mA (slow blow)
6.5 Vout models:
1'000 mA (slow blow)
9 Vout models:
1'000 mA (slow blow)
12 Vout models:
1'000 mA (slow blow)
15 Vout models:
1'000 mA (slow blow)
24 Vout models:
800 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Filter
See application note:
www.tracopower.com/overview/tsr0-6wi
(Recommended external input filter proposal)
Input Specifications
Voltage Set Accuracy
±2.5% max.
Regulation
- Input Variation (Vmin - Vmax)
0.9% max.
- Load Variation (10 - 100%)
0.6% max.
Ripple and Noise
(20 MHz Bandwidth)
3.3 Vout models:
50 mVp-p typ.
5 Vout models:
50 mVp-p typ.
6.5 Vout models:
50 mVp-p typ.
9 Vout models:
50 mVp-p typ.
12 Vout models:
50 mVp-p typ.
15 Vout models:
50 mVp-p typ.
24 Vout models:
75 mVp-p typ.
Capacitive Load
100 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
50 ms typ. (24 Vout model)
25 ms typ. (other models))
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
200% typ. of Iout max.
Transient Response
- Peak Variation
90 mV typ. / 180 mV max. (50% Load Step)
- Response Time
150 µs typ. / 250 µs max. (50% Load Step)
Output Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
3.57 %/K above 77°C
Over Temperature
Protection Switch Off
- Protection Mode
165°C typ. (Automatic recovery)
- Measurement Point
Internal IC temperature
Cooling System
Natural convection (20 LFM)
Switching Frequency
117 - 243 kHz (PWM) (3.3 Vout model)
130 - 270 kHz (PWM) (5 Vout model)
163 - 338 kHz (PWM) (6.5 Vout model)
195 - 405 kHz (PWM) (9 Vout model)
247 - 513 kHz (PWM) (12 Vout model)
293 - 608 kHz (PWM) (15 Vout model)
416 - 864 kHz (PWM) (24 Vout model)
Insulation System
Non-isolated
Reliability
- Calculated MTBF
18'160'000 h (MIL-HDBK-217F, ground benign)
General Specifications
TSR 0.6WI Series, 0.6 A
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
April 27, 2020
Page 2 / 4