All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Industrial Power Supplies
TSP-WR Series 180600 Watt
Input Specifications
Applicable 3-Phase Networks – TN, TT: 500 VAC Star configuration (EN60950+UL508)
500 VAC Delta (UL508 only)
– IT: 400 VAC Delta (IEC-62103)
230 VAC Delta (IEC-60950)
500 VAC UL508 only
Input voltage ranges 85–132 VAC, 50/60Hz
187264 / 323–550 VAC, 50/60Hz
range selectable by manual slide switch
Harmonic limits EN 61000-3-2, Class A (for limited output power)
Holdup time 20 ms min.
(full load 230 - 500 VAC)
Inrush current 115 VAC 230 VAC
TSP 180-124WR t.b.a < 23 A
TSP 360-124WR t.b.a < 46 A
TSP 600-124WR t.b.a < 50 A
Efficiency 88% typ.
Output Specifications
Output voltage adj. range 24 – 28 VDC
Regulation
– Input variation 0.5 % max.
– Load variation (10100 %) 0.5 % max.
– Load variation (10100 %) parallel mode 2.0%
Ripple and Noise (20MHz Bandwidth) 100 mV pk-pk typ. (150 mV pk-pk max. at Imax)
Electronic short circuit protection current limitation at 125% of Imax.
constant current, automatic recovery
Output overvoltage protection 34 V
Overload protection electronic overload protection
Overtemperature protection switch off at overtemperature, automatic restart
Status indicator dual color LED (green: DC ok, red: DC off)
Power-Good signal – trigger threshold:
18 - 22V
– relay output DC OK = contact closed (rated: 30VDC / 1.0A)
Max. capacitive load unlimited
General Specifications
Operating temperature range – 25°C...+70°C max. (13°F...+158°F)
(for derating see graph A on page 3)
Cooling convection cooling, no internal fan
Storage temperature 25 °C…+85 °C (– 13°F...+185°F)
Humidity (non condensing) 95 % rel. H max.
Pollution degree 2
Temperature coefficient 0.02 %/K
Reliability, calculated MTBF >350’000h in acc. to IEC 61709
Remote On/Off by ext. contact.
DC on: -S contact open
DC off: -S connectetd via 1Kohm to -Vout