Datasheet

Input Voltage
Operational Range:
85 - 264 VAC (Full Range)
Rated Range:
100 - 240 VAC (Full Range)
Operational Range:
120 - 370 VDC
Certified Range:
120 - 370 VDC
Polarity:
+DC: L / –DC: N
(When operating with DC input voltage an external
fuse T 1.0 A / 400 VDC is needed. Allowed types:
Littlefuse 477 series, Cooper Bussmann type
S505H-1-R, Bel Fuse type 0ADK)
Input Frequency
Operational Range:
47 - 440 Hz
Certified:
50/60 Hz
Input Current
300 mA max.
450 mA max.
Power Consumption
75 mW max. (Ready to meet ErP directive)
75 mW max.
Input Inrush Current
40 A max.
25 A max.
Input Protection
T 1.6 A / 250 VAC (Internal Fuse)
Recommended Input Fuse
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Output Voltage Adjustment
See application note:
±10% (By external trim resistor)
www.tracopower.com/overview/tpp15-d
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
0.2% max.
0.7% max. (3.3 and 5 VDC model)
0.5% max. (other output models)
Ripple and Noise
(20 MHz Bandwidth)
3.3 VDC model:
40 mVp-p typ. (w/ 10 µF X5R)
5 VDC model:
40 mVp-p typ. (w/ 10 µF X5R)
9 VDC model:
70 mVp-p typ. (w/ 10 µF X5R)
12 VDC model:
70 mVp-p typ. (w/ 10 µF X5R)
15 VDC model:
70 mVp-p typ. (w/ 10 µF X5R)
24 VDC model:
100 mVp-p typ. (w/ 10 µF X5R)
36 VDC model:
100 mVp-p typ. (w/ 10 µF X5R)
48 VDC model:
140 mVp-p typ. (w/ 1 µF X7R)
Capacitive Load
3.3 VDC model:
6'000 µF max.
5 VDC model:
4'000 µF max.
9 VDC model:
1'860 µF max.
12 VDC model:
1'200 µF max.
15 VDC model:
820 µF max.
24 VDC model:
470 µF max.
36 VDC model:
220 µF max.
48 VDC model:
150 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
8 ms min.
Start-up Time
500 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
120 - 200% of Iout max.
145% typ. of Iout max.
Overvoltage Protection
125 - 140% of Vout nom.
Output Specifications
TPP 15-D Series, 15 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023