All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications
Temperature ranges – Operating 10°C to +60°C
– Derating above +50°C: 5 %/K
– Storage (non operating) 20°C to +75°C
Temperature coefficient 0.02 %/K
Efficiency – Single output models 78 % typ.
– Multi output models 70 % typ.
Humidity (non condensing) 85 % rel H max.
Switching frequency – Single output models 140 kHz typ. (puls width modulation)
– Multi output models 150 kHz typ. at 50 % load (frequency modulation)
Hold-up time – Single output models Vin = 115/230 VAC 30 ms typ.
– Multi output models Vin = 115/230 VAC 20 ms typ.
I/O Isolation voltage (60 sec.) 3‘000 VAC
Leakage current 0.75 mA RMS typ. / 230 VAC / 50 Hz
ELectromagnetic compatibility (EMC), Emissions
– Conducted input RI suppression EN 55022, class B, FCC part 15, level B
– Harmonic current emissions
IEC/EN 61000-3-2, class A (75-150 Watt models)
ELectromagnetic compatibility (EMC), Immunity
– Electrostatic discharge ESD IEC/EN 61000-4-2 level 2 4 kV / 4 kV
– RF field susceptibility IEC/EN 61000-4-3 level 2 3 V /m
– Electrical fast transients/bursts on mainsline IEC/EN 61000-4-4 level 2 1 kV
– Surge IEC/EN 61000-4-5 level 2 0.5 kV / 1kV
– Voltage dip IEC/EN 61000-4-11
Safety standards IEC/EN 60950-1, cUL/UL 60950-1
Safety approvals – UL/cUL 60950 -1 www.ul.com -> certifications -> File e141988
– CB report (IEC 60950-1, 2nd edition)
www.tracopower.com/products/tof-cb.pdf
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >250‘000 h
Vibration 1055 Hz 0.5 mm width/ 1 minute cycle
(3 directions each 30 minutes)
Shock 20 G (3 directions each 3 times)
Environmental compliance – Reach www.tracopower.com/products/tof-reach.pdf
– RoHS RoHS directive 2011/65/EU
AC/DC Power Supplies
TOF Series 10150 Watt