Data Sheet
  TMR 6WIR Series, 6 Watt
www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. 
Input Specifications 
Input current no load   24 Vin models:  6 mA typ 
  48 Vin models:  6 mA typ. 
  110 Vin models:  2 mA typ.
Surge voltage (1 s max.)    24 Vin models:  50 V max. 
  48 Vin models:  100 V max. 
  110 Vin models:  185 V max.
EMC emissions  – Conducted & Radiated input suppression 
EN 55011, EN 55032 class A or B (with ext. filter) 
–
 Application note for filter class A/B proposal   
www.tracopower.com/overview/tmr6wir
EMC immunity  – ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV, 
      perf. criteria A 
  – Radiated immunity EN 61000-4-3, 20 V/m, perf. criteria A 
  – Fast transient / surge    EN 61000-4-4, ±2 kV, perf. criteria A 
   (with external input capacitor / diode) EN 61000-4-5, ±2 kV perf. criteria A 
    24 Vin models:  Nippon chemi-con KY 220 µF / 100 V and 
      TVS (SMDJ70A, 70 V, 3000 W) in parallel 
  48 Vin models:  Nippon chemi-con KY 220 µF / 100 V and 
      TVS (SMDJ120A, 120 V, 3000 W) in parallel 
  110 Vin models:  Nippon chemi-con KY 150 µF / 200 V and 
      TVS (SMDJ250A, 250 V, 600 W) in parallel 
  – Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A 
  – Magnetic field immunity EN 61000-4-8 
   100 A/m, continuous, perf. criteria A   
      1000 A/m, 1 sec., perf. criteria A
Input filter      capacitor type
Recommended input fuse    24 Vin models:  1.25 A (slow blow) 
  48 Vin models:  0.63 A (slow blow) 
  110 Vin models:  0.15 A (slow blow)
Output Specifications 
Voltage set accuracy      ±1 % max.
Regulation  – Input variation (Vin min. to Vin max.)    0.2 % max. 
  – Load variation (0 – 100 %)  single output:  0.5 % max. 
  dual output:  1 % max. 
  – Cross regulation  dual output:  5 % max. (asymmetrical load 25 % / 100 %)
Temperature coefficient      ±0.02 %/K max.
Minimum load      not required
Ripple and noise (20 MHz Bandwidth with 1 µF / 50 V)    75 mVp-p max.
Start up time (constant resistive load)    75 ms max.
Transient response  – Recovery time (25% load step change)    250 µs typ.
Current limitation      180 % of Iout nom. typ. (hiccup)
Short circuit protection      continuous, automatic recovery
Capacitive load  – Single output  3.3 VDC models:  2200 µF max. 
  5.0 VDC models:  1100 µF max. 
  9.0 VDC models:  680 µF max. 
  12 & 15 VDC models:  470 µF max. 
  24 VDC models:  180 µF max. 
  – Dual output  ±5 VDC models:  680 µF max. (each output) 
    ±12 VDC models:  330 µF max. (each output) 
  +15 VDC models: 180 µF max. (each output)
General Specifications 
Temperature ranges  – Operating (natural convection: 20 LFM, 0.1 m/s)    –40°C to +80°C 
  – Case temperature    +100°C max. 
  – Storage temperature –55°C to +125°C
Derating      2.5 %/K above 60°C
Humidity (non condensing)      5 – 95 % rel H max.