Datasheet
TMR 6 Series, 6 Watt
http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current at no load 5 V models: 105 mA typ.
(nominal input voltage) 12 V models: 55 mA typ.
24 V models: 30 mA typ.
48 V models: 15 mA typ.
Surge voltage (100 msec. max.) 5 V models: 15 V max.
12 V models: 36 V max.
24 V models: 50 V max.
48 V models: 100 V max.
Input filter capacitor type. Application for compliance to
EN 55022 class A/B see supporting documents
Recommended input fuse 5 V models: 3.0 A
(slow blow, max. rating) 12 V models: 1.6 A
24 V models: 1.0 A
48 V models: 500 mA
ESD (electrostatic discharge) EN 6100042, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 6100043, 10 V/m, perf. criteria A
Fast transient / surge (with external input capacitor) EN 6100044, ±2 kV, perf. criteria A
EN 6100045, ±2 kV perf. criteria A
– external input capacitor 5 Vin models:
Nippon chemi-con KY 330 µF, 50 V, ESR 55 mOhm
other models:
Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 6100046, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1 % max
Regulation – Input variation Vin min. to Vin max. 0.2 % max.
– Load variation 0100% single out models: 1.0 % max.
dual output models: 1.0 % max. balanced load
– Load cross regulation 25/100% 5.0 % max. (dual output models)
Minimum load 0 % of rated max. load
Ripple and noise (20 MHz Bandwidth) 50 mVpk-pk max.
Transient response setting time (25% load step change) 500 µs typ.
Short circuit protection indefinite, automatic recovery
Start up time – Power On 30 ms typ.
(constant resistive load) – Remote On 30 ms typ.
Capacitive load 3.3 VDC / 5 VDC output models: 6600 µF max. / 3300 µF max.
9 VDC output models: 2000 µF max.
12 VDC / 15 VDC output models: 1600 µF max. / 1400 µF max.
24 VDC output models: 680 µF max.
±5 VDC / ±12 VDC output models: ±2000 µF max. / ± 900 µF max.
±15 VDC output models: ±660 µF max.
General Specifications
Temperature ranges – Operating –40°C to +65°C (without derating)
– Case temperature +105°C max.
– Storage –55°C to +125°C
Load derating 4 %/K above 65°C
Thermal shock, mechanical shock & vibration EN 61373, MILSTD810F
– Test conditions www.tracopower.com/products/mil810.pdf
Humidity (non condensing) 95 % rel. H max.
Temperature coefficient ±0.02 %/K