Datasheet

Input Current
- At no load
5 Vin models:
105 mA typ.
12 Vin models:
55 mA typ.
24 Vin models:
28 mA typ.
48 Vin models:
14 mA typ.
Surge Voltage
5 Vin models:
15 VDC max. (1 s max.)
12 Vin models:
36 VDC max. (1 s max.)
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
Under Voltage Lockout
5 Vin models:
2 VDC min. / 3.5 VDC typ. / 4 VDC max.
12 Vin models:
5 VDC min. / 7 VDC typ. / 8 VDC max.
24 Vin models:
12 VDC min. / 15 VDC typ. / 17 VDC max.
48 Vin models:
26 VDC min. / 33 VDC typ. / 35 VDC max.
Recommended Input Fuse
5 Vin models:
3'000 mA (slow blow)
12 Vin models:
1'600 mA (slow blow)
24 Vin models:
1'000 mA (slow blow)
48 Vin models:
500 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Filter
Internal Capacitor
Input Specifications
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
dual output models:
0.2% max.
- Load Variation (0 - 100%)
single output models:
1% max.
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
- 20 MHz Bandwidth
50 mVp-p typ.
Capacitive Load
- single output
3.3 Vout models:
6'600 µF max.
5 Vout models:
3'300 µF max.
9 Vout models:
2'000 µF max.
12 Vout models:
1'600 µF max.
15 Vout models:
1'400 µF max.
24 Vout models:
680 µF max.
- dual output
5 / -5 Vout models:
2'000 / 2'000 µF max.
12 / -12 Vout models:
900 / 900 µF max.
15 / -15 Vout models:
600 / 600 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
5 ms typ. / 10 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Transient Response
- Response Time
500 µs typ. (25% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tmr6
Pollution Degree
PD 2
Safety Specifications
TMR 6 Series, 6 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023