Datasheet

Standards
EN 62368-1
IEC 62368-1
UL 62368-1
EN 60335-1
IEC 60335-1
IEC 61558-1
IEC 61558-2-16
www.tracopower.com/overview/tmpw5
Protection Class
Class I & II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 55032 class B (internal filter)
EN 55032 class B (internal filter)
EN 61000-3-2, class A
EN 61000-3-3
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-6-2 (Generic Industrial)
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±1 kV, perf. criteria A
L to L:
EN 61000-4-5, ±2 kV, perf. criteria A
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous:
EN 61000-4-8, 30 A/m, perf. criteria A
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 10 periods, perf. criteria B
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
100%, 1 period, perf. criteria A
100%, 250 periods, perf. criteria B
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 10 periods, perf. criteria B
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
100%, 1 period, perf. criteria A
100%, 250 periods, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
–40°C to +70°C
–40°C to +85°C
Power Derating
2.5 %/K above 50°C (High Temperature)
2.0 %/K below –30°C (Low Temperature)
See application note:
www.tracopower.com/overview/tmpw5
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max. (acc. IEC 62368-1)
2'000 m max. (acc. IEC 60335-1)
Switching Frequency
60 - 150 kHz (PWM, PFM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
314 VAC
Isolation Test Voltage
4'000 VAC
General Specifications
TMPW 5 Series, 5 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 27, 2023
Page 3 / 5