Datasheet
Protection Class
Class I & II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
EMI Emissions
- Conducted Emissions
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
- Voltage Fluctuations & Flicker
EN 61000-3-3
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-6-2 (Generic Industrial)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 10 periods, perf. criteria A
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
100%, 0.5 periods, perf. criteria A
100%, 1 period, perf. criteria A
100%, 250 periods, perf. criteria B
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 10 periods, perf. criteria A
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
100%, 0.5 periods, perf. criteria A
100%, 1 period, perf. criteria A
100%, 250 periods, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +70°C
- Storage Temperature
–40°C to +85°C
Power Derating
- High Temperature
2.5 %/K above 50°C
- Low Input Voltage
2 %/V below 100 VAC
See application note:
www.tracopower.com/overview/tmpw10
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max. (acc. IEC 62368-1)
2'000 m max. (acc. IEC 60335-1)
Switching Frequency
35 - 75 kHz (PWM, PFM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
254 VAC
Isolation Test Voltage
- Input to Output, 60 s
4'000 VAC
Leakage Current
- Touch Current
250 µA max.
Reliability
- Calculated MTBF
450'000 h (MIL-HDBK-217F, ground benign)
Washing Process
Not allowed
Environment
- Vibration
IEC 60068-2-6
2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle
- Mechanical Shock
IEC 60068-2-27
Housing Material
Plastic resin (UL 94 V-0 rated)
General Specifications
TMPW 10 Series, 10 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 27, 2023
Page 3 / 4