Datasheet
Input Voltage
- AC Range
Operational Range:
90 - 305 VAC (Full Range)
Rated Range:
100 - 277 VAC (Full Range)
- DC Range
Operational Range:
100 - 430 VDC
Certified Range:
100 - 250 VDC
Polarity:
+DC: N / –DC: L
(The rated range refers to 62368-1. For
60335-1 certification the rated input voltage is
100 - 240 VAC and DC input is not permitted.)
Input Frequency
Operational Range:
47 - 440 Hz
Certified:
50/60 Hz
Input Current
- Full Load & Vin = 230 VAC
140 mA max.
- Full Load & Vin = 115 VAC
230 mA max.
Power Consumption
- No load & Vin = 230 VAC
100 mW max. (Ready to meet ErP directive)
- No load & Vin = 115 VAC
100 mW max.
Input Inrush Current
- At 230 VAC
60 A max.
- At 115 VAC
30 A max.
Recommended Input Fuse
1'600 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (0 - 100%)
1% max. (5 & 12 Vout models)
0.5 % max. (other models)
Ripple and Noise
(20 MHz Bandwidth)
5 VDC model:
60 mVp-p max. (w/ 0.1 µF || 47 µF)
12 VDC model:
120 mVp-p max. (w/ 0.1 µF || 47 µF)
15 VDC model:
150 mVp-p max. (w/ 0.1 µF || 47 µF)
24 VDC model:
240 mVp-p max. (w/ 0.1 µF || 47 µF)
Capacitive Load
5 VDC model:
3'500 µF max.
12 VDC model:
700 µF max.
15 VDC model:
390 µF max.
24 VDC model:
180 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
- At 230 VAC
30 ms min.
Start-up Time
- At 230 VAC
60 ms max.
- At 115 VAC
60 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
140 - 235% of Iout max.
Overvoltage Protection
105 - 145% of Vout nom.
(By Zener diode)
Transient Response
- Response Deviation
2% typ. / 3% max. (50% to 75% Load Step)
- Response Time
500 µs max. (50% to 75% Load Step)
Output Specifications
Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Household
EN 60335-1
IEC 60335-1
- Power Transformers
IEC 61558-1
IEC 61558-2-16
- Certification Documents
www.tracopower.com/overview/tmpw10
Safety Specifications
TMPW 10 Series, 10 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 27, 2023
Page 2 / 4