Datasheet
Safety Standards
- IT / Multimedia Equipment
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
UL 60950-1
UL 62368-1
- Household
EN 60335-1
IEC 60335-1
- Certification Documents
www.tracopower.com/overview/tmps05
Protection Class
Class I & II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 61204-3 (Low Voltage Power Supplies)
- Conducted Emissions
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
FCC Part 15 class B (internal filter)
- Radiated Emissions
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
FCC Part 15 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2
- Voltage Fluctuations & Flicker
EN 61000-3-3
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 55014-2 (Household Appliances Tools)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 5 periods, perf. criteria A
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–25°C to +70°C
- Storage Temperature
–40°C to +85°C
Power Derating
- High Temperature
2.5 %/K above 50°C
See application note:
www.tracopower.com/overview/tmps05
Cooling System
Natural convection (20 LFM)
Altitude During Operation
4'000 m max.
Switching Frequency
49 - 81 kHz (PWM)
65 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
250 VAC
Isolation Test Voltage
- Input to Output, 60 s
3'000 VAC
Isolation Resistance
- Input to Output, 500 VDC
100 MΩ min.
Reliability
- Calculated MTBF
520'000 h (MIL-HDBK-217F, ground benign)
Washing Process
Not allowed
General Specifications
TMPS 05 Series, 5 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023