Datasheet

Input Voltage
Operational Range:
85 - 264 VAC (Full Range)
Rated Range:
100 - 240 VAC (Full Range)
Operational Range:
120 - 370 VDC (Designed for, no certification)
Polarity:
irrelevant
Input Frequency
Operational Range:
47 - 63 Hz
Certified:
50/60 Hz
Power Consumption
750 mW max.
300 mW max.
Input Inrush Current
40 A max.
20 A max.
Input Protection
T 1.0 A / 250 V
Recommended Input Fuse
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
1% max.
1% max.
Boost Power
Output Current peak: See model table
Peak power time: 30 s max.
Peak power duty cycle: 10% max.
Average operation power: 5 W max.
Ripple and Noise
(20 MHz Bandwidth)
3.3 VDC model:
60 mVp-p max.
5 VDC model:
60 mVp-p max.
9 VDC model:
90 mVp-p max.
12 VDC model:
120 mVp-p max.
15 VDC model:
150 mVp-p max.
24 VDC model:
240 mVp-p max.
48 VDC model:
480 mVp-p max.
Capacitive Load
3.3 VDC model:
2'200 µF max.
5 VDC model:
1'000 µF max.
9 VDC model:
300 µF max.
12 VDC model:
160 µF max.
15 VDC model:
100 µF max.
24 VDC model:
43 µF max.
48 VDC model:
10 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.05 %/K max.
Hold-up Time
40 ms min.
8 ms min.
Start-up Time
200 ms max.
200 ms max.
Start-up Overshoot Voltage
5% max.
Short Circuit Protection
Continuous, Automatic recovery
Overload Protection
Foldback Mode
Output Current Limitation
135% min. of Iout max.
150% typ. of Iout max.
Overvoltage Protection
125% typ. of Vout nom.
190% max. of Vout nom.
(By Zener diode)
Output Specifications
TMPS 05 Series, 5 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 2 / 5