All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Max. capacitive load [µF] Model series
Output:
TMPM 04 TMP 07 TMPM 10
TMP 10 TMP 15 TMP 30 TMP 60
Single output
models:
3.3 VDC 1200 2200 2200 3900 - - -
5.0 / 5.1 VDC 800 2200 2200 3300 3900 8000 8000
9.0 VDC 440 - - - - - -
12 / 15 VDC 260 1000 1000 2200 2200 3900 3900
24 VDC 160 680 680 1000 1000 1500 1500
36 VDC - - - - - - 1000
48 VDC - - - - 680 1000 800
Dual output
models:
3.3 / 5.0 VDC 4700 - - - 2000 3900 -
+12 / –12 / +15 / –15 VDC 260 - - 1000 1500 1500 -
Triple output
models:
3.3 / 5.0 VDC - - - - 2200 2200 -
+12 / –12 / +15 / –15 VDC - - - - 1500 1500 -
Input Specifications
Input voltage – nominal 100 – 240 VAC
– AC range (universal input) 85 – 264 VAC
– DC range 120 – 370 VDC
Input frequency – nominal 50 / 60 Hz
range 4 – 30 W models: 47 – 440 Hz
60 W models: 47 – 63 Hz
Input current at full load 115 VAC / 230 VAC input 4 W models: 80 mA / 55 mA typ.
7 W models: 150 mA / 100 mA typ.
10 W models: 200 mA / 130 mA typ.
15 W models: 300 mA / 190 mA typ.
30 W models: 550 mA / 330 mA typ.
60 W models: 1050 mA / 670 mA typ.
Recommended external input fuse 4 W models: 1.0 A slow blow
7 – 15 W models: 2.0 A slow blow
30 W models: 3.5 A slow blow
60 W models: 6.3 A slow blow
Output Specifications
Voltage set accuracy ±2 % max.
Regulation – Input variation Output 1 1 % max.
– Input variation Output 2/3 3 % max.
– Load variation TMPM 04103 model (0100%): 1.5 % max.
single and floating outputs (10–100%): 1 % max. (0100% for TMPM 04 models)
common ground outputs balanced load (10100%): 2.5 % max.
common ground outputs unbalanced load (20/90%): 5.0 % max.
Minimum load TMPM 04 single and sym.dual models: not required
TMPM 04 asym. dual models: 25% per output
single and dual output models:
10 % of rated max. current
triple output models main output:
10 % of rated max. current
triple output models auxiliary outputs:
20 % of rated max. current
operation at lower load condition will not
damage these power supplies, how ever, they
may not meet all listed specifications.
Ripple and noise (20MHz bandwidth) 3.3 VDC & 5.0 VDC outputs: 1.8 % of Vout [mVp-p]
other outputs: 1.0 % of Vout [mVp-p]
Overload protection by current limit 105 % min. of Inom, fold back, automatic
recovery (long term overload condition may
cause damage to the power supply)
Overvoltage protection by Zener diode (main output only) 120 % of Vout typ.
Start-up time 400 ms typ.
Hold-up time 20 ms typ.
AC/DC Power Modules