Datasheet
http://www.tracopower.com Page 3 of 6
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Modules
TML Series 5 to 30 Watt
Output Specifications
Voltage set accuracy ± 2 %
Regulation
– Input variation 0.3 % max.
– Load variation (10–100%)
– Single output models 1.0 % max.
– Dual/ triple output models 5 % max.
Minimum load 5 % for TML 30 single output models
10 % on main output of triple output models
Ripple and noise (20 MHz Bandwidth) – 3.3 & 5 VDC output models: < 1.5 % of Vout
– other models: < 1.0 % of Vout
Current limitation 120 – 180 % fold back
Short circuit protection hiccup mode, indefinite (automatic recovery)
Maximum capacitive load 470 – 50’000 µF depending on model
General Specifications
Temperature ranges – Operating – 25 °C…+71 °C
– Power derating above 50°C 3.75 %/°C
– Storage (non operating) – 40 °C…+85 °C
Temperature coefficient 0.02 % / °C
Efficiency 72 – 80 %
(depending on model)
Humidity (non condensing) 95 % rel max.
Switching frequency 100 kHz typ. (Puls width modulation PWM)
Hold-up time 40 ms min.
(Vin 115...230 VAC)
Isolation voltage
– Input/ Output 3‘000 VAC
Reliability /calculated MTBF (MIL-HDBK-217E) > 660’000 h @ 25°C
EMI / RFI conducted EN 55022, class B, FCC part 15, level B
EMC compliance
– Electrostatic discharge ESD IEC / EN 61000-4-2 4 kV / 8 kV
– RF field susceptibility IEC / EN 61000-4-3 3 V/m
– Electrical fast transients/bursts on mainsline IEC / EN 61000-4-4 1 kV
Safety Class II (only 30 watt models) to IEC / EN 60536
Safety standards UL 1950, IEC 60950, EN 60950
Safety approval cUL /UL File E188913
www.ul.com -> certifications
Case material Plastic resin + Fiberglass
(flammability to UL 94-V0)