Data Sheet

Input Current
- at no load
24 Vin models:
30 mA typ.
48 Vin models:
20 mA typ.
- at full load
24 Vin models:
490 mA typ.
48 Vin models:
245 mA typ.
Surge Voltage
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
Under Voltage Lockout
24 Vin models:
8 VDC typ.
48 Vin models:
16 VDC typ.
Input Filter
Internal Pi-Type
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.5% max.
dual output models:
0.5% max.
- Load Variation (0 - 100%)
single output models:
0.5% max.
dual output models:
0.5% max. (Output 1)
0.5% max. (Output 2)
- Cross Regulation
(symmetrical load)
dual output models:
2% max.
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
(20 MHz Bandwidth)
- single output
5.1 Vout models:
90 mVp-p typ.
12 Vout models:
90 mVp-p typ.
15 Vout models:
90 mVp-p typ.
24 Vout models:
180 mVp-p typ.
48 Vout models:
180 mVp-p typ.
- dual output
12 / -12 Vout models:
90 / 90 mVp-p typ.
15 / -15 Vout models:
90 / 90 mVp-p typ.
24 / -24 Vout models:
180 / 180 mVp-p typ.
Capacitive Load
- single output
5.1 Vout models:
1'000 µF max.
12 Vout models:
470 µF max.
15 Vout models:
330 µF max.
24 Vout models:
150 µF max.
48 Vout models:
68 µF max.
- dual output
12 / -12 Vout models:
220 / 220 µF max.
15 / -15 Vout models:
150 / 150 µF max.
24 / -24 Vout models:
68 / 68 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
60 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Transient Response
- Response Deviation
5% max. (75% to 100% Load Step)
- Response Time
500 µs max. (75% to 100% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tmdc10
Pollution Degree
PD 3
Safety Specifications
TMDC 10 Series, 10 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
July 15, 2019
Page 2 / 4