Data Sheet

Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Medical Equipment
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Certification Documents
www.tracopower.com/overview/tim2
Pollution Degree
PD 2
Safety Specifications
EMI Emissions
EN 60601-1-2 edition 4 (Medical Devices)
- Conducted Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
FCC Part 18, class B
- Radiated Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
FCC Part 18, class B
- External Filter Proposal
www.tracopower.com/overview/tim2
EMS Immunity
EN 60601-1-2 edition 4 (Medical Devices)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±15 kV, perf. criteria A
Contact:
EN 61000-4-2, ±8 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. Input Component:
9 Vin models: KY 1000 µF // TVS SMDJ18A
12 Vin models: KY 470 µF
24 Vin models: KY 470 µF
48 Vin models: KY 220 µF
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +95°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
6.67 %/K above 90°C
Cooling System
Natural convection (20 LFM)
Remote Control
- Current Controlled Remote
On: open circuit
Off: 2 to 4 mA current (internal 1 kOhm resistor)
- External Circuit Proposal
www.tracopower.com/info/current-remote.pdf
- Off Idle Input Current
2.5 mA typ.
Altitude During Operation
5'000 m max.
Switching Frequency
100 kHz min. (RCC)
Insulation System
Reinforced Insulation
Working Voltage (rated)
250 VAC
Isolation Test Voltage
- Input to Output, 60 s
5'000 VAC
Creepage
- Input to Output
8 mm min.
Clearance
- Input to Output
8 mm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
16 pF typ.
20 pF max.
Leakage Current
- Touch Current
2 µA max. (240 VAC, 60 Hz)
Reliability
- Calculated MTBF
6'809'000 h (MIL-HDBK-217F, ground benign)
General Specifications
TIM 2 Series, 2 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
July 16, 2019