Data Sheet
Input Current
- at no load
9 Vin models:
80 mA typ.
12 Vin models:
40 mA typ.
24 Vin models:
25 mA typ.
48 Vin models:
12 mA typ.
Surge Voltage
9 Vin models:
15 VDC max. (1 s max.)
12 Vin models:
25 VDC max. (1 s max.)
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
Under Voltage Lockout
9 Vin models:
2 VDC min. / 3 VDC typ. / 4 VDC max.
12 Vin models:
6 VDC min. / 7 VDC typ. / 8 VDC max.
24 Vin models:
13 VDC min. / 15 VDC typ. / 17 VDC max.
48 Vin models:
29 VDC min. / 32 VDC typ. / 35 VDC max.
Recommended Input Fuse
9 Vin models:
1000 mA (slow blow)
12 Vin models:
500 mA (slow blow)
24 Vin models:
315 mA (slow blow)
48 Vin models:
160 mA (slow blow)
Input Filter
Internal Capacitor
Input Specifications
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
dual output models:
0.2% max.
- Load Variation (10 - 90%)
single output models:
0.5% max.
dual output models:
0.8% max. (Output 1)
0.8% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
- 20 MHz Bandwidth
50 mVp-p typ.
Capacitive Load
- single output
3.3 Vout models:
1'000 µF max.
5 Vout models:
1'000 µF max.
9 Vout models:
430 µF max.
12 Vout models:
220 µF max.
15 Vout models:
170 µF max.
24 Vout models:
100 µF max.
- dual output
12 / -12 Vout models:
170 / 170 µF max.
15 / -15 Vout models:
100 / 100 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
10 ms typ. / 20 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Overload Protection
Foldback Mode
Overvoltage Protection
104 - 197% of Vout nom.
(depending on model)
4 - 6.5 VDC (3.3 Vout models)
6 - 8 VDC (5 Vout models)
10 - 14 VDC (9 Vout models)
13 - 19 VDC (12 Vout models)
16 - 22 VDC (15 Vout models)
25 - 35 VDC (24 Vout models)
Transient Response
- Response Time
500 µs typ. (25% Load Step)
Output Specifications
TIM 2 Series, 2 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
July 16, 2019
Page 2 / 4