Data Sheet
www.tracopower.com Page 2 of 6
  TIB 120EX Series, 120 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. 
Input Specifications
Input voltage    – nominal ranges    100 – 240 VAC 
 – effective ranges    85 – 264 VAC 
     (below 90 VAC a derating of 3%/V is required)
Input voltage frequency      45 – 65 Hz
Standby power cunsumption 2.2/2.2 W (115 / 23 0  VA C)
Power Factor Correction (PFC)     0.97/0.8 (115 /2 3 0  V AC )
Harmonic limits  – acc. EN 61000-3-2    class A, D
Inrush current        15/30 A max. (115 /2 3 0  V AC )  
Output Specifications 
Output voltage adjustment 
1)
      12 Vout models:  11.8 – 15.0 V  
     24 Vout models:  23.5 – 28.0 V  
     48 Vout models:  47.0 – 56.0 V
Regulation  – Input variation      0.1 % max. 
  – Load variation (10–90 %)      0.5 % max.
Temperature coefficient          0.02 %/K
Hold-up time        20 ms min.
Start-up time     2 s  max.
Ripple and Noise (20MHz bandwidth)   12 & 24 Vout models: 100 mVp-p max.  
     48 Vout models:  200 mVp-p max.
Output overvoltage protection (OVP) 
2)
   12 Vout models:  16 – 19 V  
     24 Vout models:  32 – 35 V  
     48 Vout models:  56 – 60 V
Power back immunity 
3)
     < OVP level
Operation  – Nominal operation      100 % of Iout nom. 
  – Peak power operation      105 – 150 % of Iout nom. 
  – Constant current (cc)      > 155 % of Iout nom.
Duty cycle 
4)
  – Threshold        > 105 % 
(for peak and cc mode)  – CC or peak opeartion timer      4 s max. (switch off) 
  – normal operation / off period    10 s typ. (automatic restart after switch off or   
          peak and cc operation timer reset)   
Short circuit          Switch off after 4s delay, automatic restart 
DC OK signal  – Threshold for Vout 12 Vout models:  on: > 10.9 V typ., off: < 10.7 V  typ.     
     24 Vout models:  on: > 22.5 V typ., off: < 21.5 V typ.     
     48 Vout models:  on: > 45 V typ., off: < 43 V typ.     
  – DC ON        relay contact closed, 1 A max., < 100 mOhm 
       (also indicated by green LEDs: front and side) 
  – DC OFF        relay contact open, 30 V max.   
1) 
Output  voltage  can  be  adjusted  as  indicated.  However,  output  power  has  to  be  maintained  at  nominal  value.  This  means  the  output 
nominal current has to be reduced in accordance with the increase of output voltage.
2) 
In case of an internal error a second voltage regulation loop keeps the output voltage at a save level, the power supply turns off and 
 restarts after typ. 10 seconds.
3) 
When external voltage is supplied above set output voltage and below OVP threshold, the power supply will function normally without 
 switch off or destruction, even if external voltage is applied continuously.
4) 
In case of overload or short circuit, the unit switches the output voltage off after 4 seconds and tries to restart every typ. 10 seconds.