All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. 
General Specifications
Capacitive load  –Single output  3.3 VDC models:  2‘100 F max. 
   5.0 VDC models:  1‘500 F max.  
  12 VDC models:  260 F max. 
  15 VDC models:  210 F max. 
  24 VDC models:  75 F max. 
  –Dual output  ±5 VDC models:  860 F max. (each output) 
  ±12 VDC models:  150 F max. (each output) 
    ±15 VDC models:  110 F max. (each output)
Temperature ranges  – Operating (designed for)    –40°C to +88°C (without derating) 
  – Rated according to IEC/EN 60601-1    –40°C to +70°C (without derating) 
  – Case temperature    +105°C max. 
  – Storage temperature –55°C to +125°C
Thermal  impedance      18 K/W
Humidity (non condensing)      5 % to 95 % rel H max.
Isolation voltage  – to meet ES/IEC/EN 60601-1    5000 VACrms, rated for 250 VACrms working 
(50Hz, 60sec)      voltage,  2  MOPP
Clearance/creepage     8 mm min.
Leakage current ( at  240 VAC,  60 Hz)      2 A  max.
Isolation capacitance (input/output)    17 pF max.
Altitude during operation      5000 m
Temperature coefficient      ±0.02 %/K typ.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign)    4‘700‘000 h
Switching frequency      250 kHz ±25 kHz (pulse width modulation)
Vibration and thermal shock resistance       according to MIL-STD-810F
Safety standards/approvals  – Medical equipment ANSI/AAMI ES60601-1:2005/(R)2012, 
      IEC/EN60601-1 3rd edition 
  – Certification documents www.tracopower.com/products/overview/thm6
Environmental compliance  – Reach www.tracopower.com/products/reach-declaration.pdf 
  – RoHS RoHS directive 2011/65/EU
Physical Specifications
Casing material      non-conductive black plastic
Base material      non-conductive black plastic
Potting material      silicone (UL94 V-0 rated)
Package weight      14 g (0.48oz)
Soldering temperature      max. 265°C / 10 sec
- The component is not be used in an oxygen rich environment.
- The component is not to be used in conjunction with flammable anaesthetics and agents.
- The component has to be disposed appropriately. Please refer to local regulations (Waste Electrical and Electronic Equipment).
- A modification of the component is not allowed.