100W Single Output
Output Specification (continued)
Parameter Device Min Typ Max Unit
Dynamic Load Response
(I
O
/ t = 1A/10µS ; V
in
= V
in nom
, T
A
= 25°C)
Load step change between 75% to 100% of I
out max.
Peak Deviation
TEP 100-xx10
TEP 100-xx11
TEP 100-xx12
TEP 100-xx13
TEP 100-xx15
TEP 100-xx16
TEP 100-xx18
210
210
350
470
1110
1110
1600
mV
mV
mV
mV
mV
mV
mV
Setting Time (V
out
< 10% peak deviation)
All
200
µS
Output Current TEP 100-xx10
TEP 100-xx11
TEP 100-xx12
TEP 100-xx13
TEP 100-xx15
TEP 100-xx16
TEP 100-xx18
0
0
0
0
0
0
0
25.0
20.0
8.4
6.7
4.2
3.6
2.1
A
A
A
A
A
A
A
Output Over Voltage Protection
(Non-latch Hiccup)
TEP 100-xx10
TEP 100-xx11
TEP 100-xx12
TEP 100-xx13
TEP 100-xx15
TEP 100-xx16
TEP 100-xx18
3.795
5.75
13.80
17.25
27.60
32.20
55.20
4.29
6.50
15.60
19.50
31.20
36.40
62.40
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Output Over Current Protection (Hiccup Mode) All 110 140
% I