Datasheet

Overvoltage Protection
115 - 130% of Vout nom.
Transient Response
- Response Time
200 µs typ. / 250 µs max. (25% Load Step)
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tep100
Safety Specifications
EMI Emissions
- Conducted Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/tep100
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Ext. input component:
2 x KY 220 µF
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +75°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
Depending on model
See application note:
www.tracopower.com/overview/tep100
Over Temperature
Protection Switch Off
- Protection Mode
115°C typ. (Automatic recovery at 105°C typ.)
- Measurement Point
See application note:
www.tracopower.com/overview/tep100
Cooling System
Natural convection (20 LFM)
Sense Function
10% max. of Vout nom.
Remote Control
- Voltage Controlled Remote
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
3 mA typ.
- Remote Pin Input Current
-0.5 to 1.0 mA
(Optional models with inverse Remote On/Off
function (passive = off))
Altitude During Operation
2'000 m max. (for basic insulation)
5'000 m max. (for functional insulation)
Switching Frequency
270 - 330 kHz (PWM)
300 kHz typ. (PWM)
Insulation System
Basic Insulation
Isolation Test Voltage
- Input to Output, 60 s
3'000 VDC
- Input to Case, 60 s
1'600 VDC
- Output to Case, 60 s
1'600 VDC
General Specifications
TEP 100 Series, 100 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 5