Input Current
- At no load
12 Vin models:
130 mA typ.
24 Vin models:
120 mA typ.
48 Vin models:
70 mA typ.
- At full load
12 Vin models:
9'400 mA max.
24 Vin models:
4'600 mA max.
48 Vin models:
2'300 mA max.
Surge Voltage
12 Vin models:
36 VDC max. (1 s max.)
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
Under Voltage Lockout
12 Vin models:
7.5 VDC typ.
24 Vin models:
16 VDC typ.
48 Vin models:
34 VDC typ.
Recommended Input Fuse
12 Vin models:
20'000 mA (fast acting)
24 Vin models:
10'000 mA (fast acting)
48 Vin models:
5'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Reverse Voltage Protection
Parallel diode (external input fuse required)
Input Filter
Internal Pi-Type
Input Specifications
Output Voltage Adjustment
–20% to +10% (By external trim resistor)
See application note:
www.tracopower.com/overview/tep100
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
0.1% max.
- Load Variation (0 - 100%)
0.1% max.
Ripple and Noise
(20 MHz Bandwidth)
3.3 Vout models:
75 mVp-p max. (w/ 4.7 µF X7R)
5 Vout models:
75 mVp-p max. (w/ 4.7 µF X7R)
12 Vout models:
100 mVp-p max. (w/ 4.7 µF X7R)
15 Vout models:
100 mVp-p max. (w/ 4.7 µF X7R)
24 Vout models:
200 mVp-p max. (w/ 4.7 µF X7R)
28 Vout models:
200 mVp-p max. (w/ 4.7 µF X7R)
48 Vout models:
300 mVp-p max. (w/ 2.2 µF X7R)
Capacitive Load
3.3 Vout models:
75'700 µF max.
5 Vout models:
40'000 µF max.
12 Vout models:
7'000 µF max.
15 Vout models:
4'460 µF max.
24 Vout models:
1'750 µF max.
28 Vout models:
1'280 µF max.
48 Vout models:
430 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
25 ms typ.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
110 - 140% of Iout max.
Output Specifications
TEP 100 Series, 100 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023