Datasheet
Application Note
Created by Traco Electronic AG Arp. www.tracopower.com Date: December 5
th
, 2011 / Rev.: 1.0 / Page 2 / 22
1W
SINGLE
AbsoluteMaximumRating
Parameter Model Min Max Unit
Input Voltage 5Vdc Input Models -0.7 9
12Vdc Input Models -0.7 18
Input Surge Voltage (1 second)
24Vdc Input Models -0.7 30
Vdc
Operating Ambient Temperature
Without Derating
All -40 +85 °C
Operating Case Temperature All --- +90 °C
Storage Temperature All -50 +125 °C
OutputSpecification
Parameter Model Min Nominal Max Unit
Output Regulation
Line (V
in min
to V
in max
at Full Load)
All ±1.05 ±1.2 %
Output Regulation TRV 1-0511 6.2
TRV 1-0519 5.5
TRV 1-0512 5.5
TRV 1-0513 5
TRV 1-1211 5
TRV 1-1219 3.3
TRV 1-1212 3.6
TRV 1-1213 2.9
TRV 1-2411 5
TRV 1-2419 3.5
TRV 1-2412 3.5
Load (20% to 100% of Full Load)
TRV 1-2413 3
%
Output Ripple & Noise
Peak-to-Peak (5Hz to 20MHz bandwidth)
30 60 mV pk-pk
Temperature Coefficient All ±0.01 ±0.02 %/℃
TRV 1-xx11 4 200
TRV 1-xx19 2 110
TRV 1-xx12 1.5 84
Output Current
TRV 1-xx13 1 67
mA
Output Short Circuit Protection All 0.5 Second Max.