Datasheet

Input Current
- at no load
12 Vin models:
20 mA typ.
24 Vin models:
15 mA typ.
48 Vin models:
10 mA typ.
- at full load
12 Vin models:
1430 mA typ.
24 Vin models:
706 mA typ.
48 Vin models:
355 mA typ.
Surge Voltage
12 Vin models:
25 VDC max. (100 ms max.)
24 Vin models:
50 VDC max. (100 ms max.)
48 Vin models:
100 VDC max. (100 ms max.)
Under Voltage Lockout
12 Vin models:
7.5 VDC typ.
24 Vin models:
15 VDC typ.
48 Vin models:
33 VDC typ.
Reflected Ripple Current
12 Vin models:
100 mAp-p typ.
24 Vin models:
50 mAp-p typ.
48 Vin models:
30 mAp-p typ.
Input Filter
Internal Pi-Type
Input Specifications
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.5% max.
dual output models:
0.5% max.
- Load Variation (0 - 100%)
single output models:
0.5% max.
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(symmetrical load)
dual output models:
2% max.
Ripple and Noise
(20 MHz Bandwidth)
- single output
5.1 Vout models:
50 mVp-p typ. (with 4.7 µF MLCC)
12 Vout models:
100 mVp-p typ. (with 4.7 µF MLCC)
15 Vout models:
100 mVp-p typ. (with 4.7 µF MLCC)
24 Vout models:
150 mVp-p typ. (with 4.7 µF MLCC)
- dual output
12 / -12 Vout models:
100 / mVp-p typ. (with 4.7 µF MLCC)
15 / -15 Vout models:
100 / mVp-p typ. (with 4.7 µF MLCC)
Capacitive Load
- single output
5.1 Vout models:
5'100 µF max.
12 Vout models:
870 µF max.
15 Vout models:
560 µF max.
24 Vout models:
220 µF max.
- dual output
12 / -12 Vout models:
440 / 440 µF max.
15 / -15 Vout models:
280 / 280 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
30 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Overvoltage Protection
120% typ. of Vout nom.
Transient Response
- Response Deviation
5% max. (75% to 100% Load Step)
- Response Time
300 µs max. (75% to 100% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tri15
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
TRI 15 Series, 15 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 25, 2019