Safety and Installation Instruction
Fusing Consideration
Caution: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of sophisticated power architecture. To maximum exibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a normal-blow fuse in 5Vin, 12Vin, 24Vin with maximum rating of 500mA, 200mA, 100mA.. Based
on the information provided in this data sheet on Inrush energy and maximum dc input current; the same type of fuse
with lower rating can be used. Refer to the fuse manufacturer’s data for further information.
MTBF and Reliability
The MTBF of TRA 1 series of DC/DC converters has been calculated using
MIL-HDBK 217F NOTICE2, Operating Temperature 25, Ground Benign.
Model MTBF Unit
TRA 1-0511
5,301,524 Hours
TRA 1-0519
3,944,773 Hours
TRA 1-0512
2,857,143 Hours
TRA 1-0513
2,343,292 Hours
TRA 1-0521
5,194,805 Hours
TRA 1-0524
3,988,036 Hours
TRA 1-0522
2,944,424 Hours
TRA 1-0523
2,419,842 Hours
TRA 1-1211
5,333,334 Hours
TRA 1-1219
3,962,358 Hours
TRA 1-1212
2,865,330 Hours
TRA 1-1213
2,348,796 Hours
TRA 1-1221
5,225,343 Hours
TRA 1-1224
4,006,009 Hours
TRA 1-1222
2,953,119 Hours
TRA 1-1223
2,425,713 Hours
TRA 1-2411
4,901,961 Hours
TRA 1-2419
3,838,771 Hours
TRA 1-2412
2,737,850 Hours
TRA 1-2413
2,262,443 Hours
TRA 1-2421
4,810,583 Hours
TRA 1-2424
3,757,633 Hours
TRA 1-2422
2,817,894 Hours
TRA 1-2423
2,333,722 Hours