Datasheet

TRA 1 Series
Application Note
http://www.tracopower.com Page 32 of 35
Mechanical Dimensions
3.2
[0.13]
10.2 [0.40]
19.5 [0.77]
T
0.50
[0.02]
Bottom View
18.5 [0.73]
0.5
[0.02]
2.35
[0.09]
2.54
[0.10]
2X2.54
[2X0.10]
0.5 [0.02]
5.08
[0.20]
0.25 [0.01]
1.3 [0.05]
1 2 4
5 6
Weight:2.2g(5&12V Input)
2.6g(24V Input)
Pin Connections
Pin Single Output Dual Output
1 +Vin +Vin
2 -Vin -Vin
4 -Vout -Vout
5 No Pin Common
6 +Vout +Vout
T=6.1[0.24] for 5V & 12V Input Models
T=7.1[0.28] for 24V Input Models
1. All dimensions in mm (inches)
Tolerance: X.X±0.25 (X.XX±0.01”)
X.XX±0.13 (X.XXX±0.005”)
2.Pin pitch tolerance:±0.25 (±0.01”)
3.Pin dimension tolerance:±0.1 (±0.004”)
Recommended Pad Layout for Single & Dual Output Converter
T
1 2
4
5
1.175 [0.05]
2.54
7.62 [0.30]
12.7[0.50]
[0.10]
6
1.All dimensions in Inches (mm)
Tolerance: x.xx±0.02” (x.x ±0.5mm)
x.xxx±0.01” (x.xx ±0.25mm)
2. Pin pitch tolerance: ±0.01” (±0.25mm)
3. Pin dimension tolerance: ±0.004” (±0.1mm)