Datasheet
TRA 1 Series
Application Note
http://www.tracopower.com Page 2 of 35
Absolute Maximum Rating
Parameter Model Min Max Unit
Input Voltage
VDC
Input Surge Voltage ( 1 sec. ) 5VDC Input Models -0.7 9
12VDC Input Models -0.7 18
24VDC Input Models -0.7 30
Operating Ambient Temperature
All
℃
Without Derating -40 +85
Operating Case Temperature All --- +90
℃
Storage Temperature All -50 +125
℃
Output Specication
Parameter Model Min Nominal Max Unit
Output Regulation
Line (V
in min
to V
in max
at Full Load) ±1.05 ±1.2
%
Output Regulation
%
Load (20% to 100% of Full Load) TRA 1-0511 6.5
TRA 1-0519 5
TRA 1-0512 5.2
TRA 1-0513 5
TRA 1-0521 5.2
TRA 1-0522 4.6
TRA 1-0523 4.5
TRA 1-1211 5
TRA 1-1219 3.4
TRA 1-1212 3.4
TRA 1-1213 2.7
TRA 1-1221 3.9
TRA 1-1222 2.9
TRA 1-1223 2.6
TRA 1-2411 3.7
TRA 1-2419 2.5
TRA 1-2412 2.4
TRA 1-2413 2.3
TRA 1-2421 3.7
TRA 1-2422 2.4
TRA 1-2423 2.3