Datasheet
Switching Frequency
50 - 140 kHz (PWM) (Output 1)
750 kHz typ. (PWM) (Output 2)
510 kHz typ. (PWM) (Output 3)
Insulation System
Reinfoced Insulation
Working Voltage (rated)
258 VAC
Isolation Test Voltage
- Input to Output, 60 s
5'657 VDC
- Input to Case or PE, 60 s
3'535 VDC
- Output to Case or PE, 60 s
3'535 VDC
Isolation Resistance
- Input to Output, 500 VDC
100 MOhm min.
Leakage Current
(at 264 VAC)
- Touch Current
75 µA max.
Creepage
8 mm min.
Clearance
8 mm min.
Reliability
- Calculated MTBF
3'000'000 h (acc. to MIL-HDBK-217F
3'000'000 h for single output models
1'700'000 h for multi output models)
Environment
- Vibration
IEC 60068-2-6
3 axis, sine sweep, 10 - 55 Hz, 1 g, 1 oct/min
- Mechanical Shock
IEC 60068-2-27
3 axis, 10 g half sine, 11 ms shock
20 g (3 directions each 3 times)
Housing Material
Aluminium
Connection Type
Screw Terminal
Weight
- single output
169 g
- dual output
216 g
- triple output
216 g
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tpp40
Blockdiagram
Outline Dimensions
Single Output Models
TPP 40 Series, 40 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
March 19, 2019
Page 4 / 5
Each one of the 4 screw holes can be used
as a PE connection for CLASS I application.
Dimensions in inch, ( ) = mm
Outside dimension tolerance: ±0.02 inch (±0.5 mm)
Hole spacing tolerance: ±0.01 inch (±0.25 mm)
Screw Terminal
Input (CON1) Output (CON2)
Pin Function Pin* Function
1
Line
1,2
–Vout
3
Neutral
3,4
+Vout
*Terminal rated for 10 A max.
(at higher current connection has to be split)