Datasheet
Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Household
IEC 60335-1
- Medical Equipment
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Power Transformers
IEC 61558-1
IEC 61558-2-16
- Certification Documents
www.tracopower.com/overview/tpp30a-d
Protection Class
Class II Prepared: Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMC Emissions
EN 60601-1-2 edition 4 (Medical Devices)
- Conducted Emissions
EN 55011 class B (internal filter)
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
FCC Part 18, class B
- Radiated Emissions
EN 55011 class B (internal filter)
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
FCC Part 18, class B
- Harmonic Current Emissions
EN 61000-3-2, class A
- Voltage Fluctuations & Flicker
EN 61000-3-3
EMC Immunity
EN 55024 (IT Equipment)
EN 60601-1-2 edition 4 (Medical Devices)
EN 55014-2 (Household Appliances Tools)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±15 kV, perf. criteria A
Contact:
EN 61000-4-2, ±8 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 20 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 1 period, perf. criteria A
>95%, 1 period, perf. criteria A
>95%, 250 periods, perf. criteria A
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 1 period, perf. criteria A
>95%, 1 period, perf. criteria A
>95%, 250 periods, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Storage Temperature
–40°C to +85°C
General Specifications
TPP 30A-D Series, 30 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 25, 2019
Page 3 / 5