Datasheet

Power Derating
- High Temperature
see application note
www.tracopower.com/overview/tpp30-d
- Low Input Voltage
4 %/V below 90 VAC
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max.
Switching Frequency
30 - 60 kHz (PWM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
272 VAC
Isolation Test Voltage
- Input to Output, 60 s
5'657 VDC
- Input to Case or PE, 60 s
2'121 VDC
- Output to Case or PE, 60 s
2'121 VDC
Creepage
- Input to Output
8 mm min.
Clearance
- Input to Output
8 mm min.
Isolation Resistance
- Input to Output, 500 VDC
100 MOhm min.
Leakage Current
(at 264 VAC)
- Touch Current
75 µA max.
Reliability
- Calculated MTBF
3'300'000 h (MIL-HDBK-217F, ground benign)
Environment
- Vibration
IEC 60068-2-6
- Mechanical Shock
IEC 60068-2-27
Connection Type
THD (Through-Hole Device)
Weight
106 g
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tpp30-d
TPP 30-D Series, 30 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 25, 2019
Page 4 / 5