Datasheet

Input Voltage
- AC Range
85 - 264 VAC (Full Range)
- DC Range
120 - 370 VDC (Designed for, no certification)
Input Frequency
47 - 63 Hz
Input Current
- Full Load & Vin = 230 VAC
300 mA max.
- Full Load & Vin = 115 VAC
450 mA max.
Power Consumption
- at no Load
75 mW max. (Ready to meet ErP directive)
Input Inrush Current
- at 230 VAC
40 A max.
Input Protection
T 1.6 A / 250 VAC (Internal Fuse)
Input Specifications
Output Voltage Adjustment
Refer to Application Note:
±10% (By external trim resistor)
www.tracopower.com/overview/tpp15-d
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (0 - 100%)
0.7% max. (3.3 and 5 VDC model)
0.5% max. (other output models)
Ripple and Noise
(20 MHz Bandwidth)
3.3 VDC model:
40 mVp-p typ. (with 10 µF X5R)
5 VDC model:
40 mVp-p typ. (with 10 µF X5R)
9 VDC model:
70 mVp-p typ. (with 10 µF X5R)
12 VDC model:
70 mVp-p typ. (with 10 µF X5R)
15 VDC model:
70 mVp-p typ. (with 10 µF X5R)
24 VDC model:
100 mVp-p typ. (with 10 µF X5R)
36 VDC model:
100 mVp-p typ. (with 10 µF X5R)
48 VDC model:
140 mVp-p typ. (with 1 µF X7R)
Capacitive Load
3.3 VDC model:
6'000 µF max.
5 VDC model:
4'000 µF max.
9 VDC model:
1'860 µF max.
12 VDC model:
1'200 µF max.
15 VDC model:
820 µF max.
24 VDC model:
470 µF max.
36 VDC model:
220 µF max.
48 VDC model:
150 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
- at 115 VAC
8 ms min.
Start-up Time
- at 230 VAC
500 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
120 - 200% of Iout max.
145% typ. of Iout max.
Overvoltage Protection
125 - 140% of Vout nom.
Transient Response
- Response Deviation
8% max. (75% to 100% Load Step)
- Response Time
500 µs typ. (75% to 100% Load Step)
Output Specifications
TPP 15-D Series, 15 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 25, 2019
Page 2 / 5