Datasheet
Protection Class
Class I (Prepared): Connection to PE
Class II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
EMI Emissions
EN 60601-1-2 edition 4 (Medical Devices)
- Conducted Emissions
EN 55011 class B (internal filter)
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
FCC Part 18, class B
- Radiated Emissions
EN 55011 class B (internal filter)
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
FCC Part 18, class B
- Harmonic Current Emissions
EN 61000-3-2, class A
- Voltage Fluctuations & Flicker
EN 61000-3-3
EMS Immunity
EN 55024 (IT Equipment)
EN 60601-1-2 edition 4 (Medical Devices)
EN 55014-2 (Household Appliances Tools)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±15 kV, perf. criteria A
Contact:
EN 61000-4-2, ±8 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
L to PE:
EN 61000-4-5, ±2 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 20 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 1 period, perf. criteria A
>95%, 1 period, perf. criteria A
>95%, 250 periods, perf. criteria A
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
60%, 1 period, perf. criteria A
>95%, 1 period, perf. criteria A
>95%, 250 periods, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Storage Temperature
–40°C to +85°C
Power Derating
- High Temperature
See application note:
www.tracopower.com/overview/tpp15a-j
- Low Input Voltage
4 %/V below 90 VAC
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max.
Switching Frequency
75 - 95 kHz (PWM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
250 VAC
Isolation Test Voltage
- Input to Output, 60 s
4'000 VAC
- Input to Case or PE, 60 s
1'500 VAC
- Output to Case or PE, 60 s
1'500 VAC
Creepage
- Input to Output
8 mm min.
Clearance
- Input to Output
8 mm min.
General Specifications
TPP 15A-J Series, 15 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
August 26, 2019
Page 3 / 5