Datasheet

http://w ww.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Supplies
TPI-100 Series 100 Watt
General Specifications
Protection class class II prepared
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B
(EMC), emissions – Harmonic current emissions IEC / EN 61000-3-2, class A & D
– Voltage flicker IEC / EN 61000-3-3, (class tba.)
– Radiated input surpression EN 55011, class A
Electromagnets compatibility – Electrostatic discharge ESD IEC / EN 61000-4-2, 8kV/6kV perf. criteria A
(EMC), immunity – RF field immunity IEC / EN 61000-4-3, 20V/m perf. criteria A
– Electrical fast transients/burst immunity IEC / EN 61000-4-4, ± 2kV perf. criteria A
– Surge IEC / EN 61000-4-5, ± 1kV/± 2kV perf. criteria A
– Conducted RF IEC / EN 61000-4-6, 20 Vr.m.s perf. criteria A
– Dip an interruptions IEC / EN 61000-4-11, (criteria tba.)
Safety standards UL 60950-1, IEC/EN 60950-1,
Safety approvals and – UL certificate (UL 60950-1) www.ul.com File e188913, copy: e188913qqgq2.pdf
certifications – CB certificate (IEC/EN 60950-1) www.tracopower.com/products/tpi100-cb60950.pdf
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10–55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 10g half sine, 11msShock
20 G (3 directions each 3 times)
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Connection pin connector
Pen ding
020406080
100
80
60
40
20
0
Output Power [%]
Ambient Temperature [°C]
(for horizontal mounting)
-25
Power derating depending on temperature